Medical Device Testing Services

January 18, 2022 news, the State Drug Administration issued a public announcement, a total of three medical device industry standards have been validated and passed. It is worth noting that YY/T 1849-2022 “recombinant collagen” will be formally implemented on August 1, 2022, Feifan test can provide you with relevant testing services, free consultation phone: 13524733472


1.Biocompatibility testing

未标题-1.png


Biocompatibility is a property of living organism tissues to react to inactive materials, generally refers to the compatibility between the material and the host. When implanted in the body, biomaterials influence and act on specific biological tissue environments, biological tissues influence and act on biomaterials, and the cycle of both continues until equilibrium is reached or the implant is removed. Biocompatibility is a consistent theme in biomaterials research.


Feifan Testing specializes in providing medical device biocompatibility testing, providing professional technical services for domestic and foreign medical device enterprises, customizing perfect testing solutions for raw materials, final products or packaging materials of medical devices, and providing a series of services such as project selection, program determination and follow-up technical support.


Test basis:

ISO 10993 & GB/T 16886 series of standards


Test item:


·  In vitro cytotoxicity test

·  Sensitization test

·  Intracutaneous reaction test

·  Eye irritation test

·  Skin irritation test

·  Oral Irritation Test

·  Vaginal Irritation Test

·  Rectal irritation test

·  Acute systemic toxicity test

·  Subacute systemic toxicity test

·  Subchronic systemic toxicity test

·  Heat source test

·  Muscle implantation test

·  Bone implantation test

·  Subcutaneous implantation test

·  In vitro hemolysis test

·  Gene mutation test

·  Chromosomal aberration test

·  Response mutation test (Ames test)

·  Mammalian in vivo micronucleus test



2.Chemical characterization of materials, leachables research (E&L)

未标题-1.png


The current GB/T 16886.1/ISO 10993.1 standard has shifted the focus from how to perform biological tests to determining the need for biological tests through methods of analyzing available information. Biological evaluation of medical devices should aim to prioritize the minimization of the number of test animals and exposure through the analysis of chemical composition and the use of in vitro models. Chemical characterization of materials provides the necessary data to support the safety evaluation of medical devices.


Leachables of medical devices is a collective term for substances released during clinical use of a medical device or material, generally including sterilization residues, process residues, degradation products, and monomers and additives (e.g., stabilizers, antioxidants, plasticizers, colorants) in the material. In the process of contact and functioning of medical device products with human body, leachables also produce safety hazards including biosafety to human body in short or long term, so it is necessary to evaluate the risk of leachables of medical devices. On the other hand, the safety study of leachables is also an important part of the biological evaluation of medical devices, and the results of the safety study can also be used to support the determination of product or material equivalence, stability studies.


Test basis:

ISO 10993.18:2020-Chemical characterization of medical device materials within a risk management process
GB/T 16886.18-2011 Biological evaluation of medical devices Part 18: Chemical characterization of materials
Guiding Principles for the Establishment of Evaluation Methods and Technical Review of Characterization of Unknown Leachables in Medical Devices

Guiding Principles for Technical Review of the Verification and Confirmation of the Determination Methods of Known Leachables for Medical Devices.


3.Pre-clinical animal experiment research          

未标题-1.png


“Before the clinical trial, the sponsor should complete the preclinical study of the test medical device, including product design (structural composition, working principle and mechanism of action, intended use and scope of application, applicable technical requirements) and quality inspection, animal testing and risk analysis, and the results should be able to support the clinical trial.” Free Consultation Tel: 13524733472

Preclinical study information should generally include:

Preclinical research information conducted by the applicant on the test medical device malefactor. For example, laboratory researchers, animal testing, etc.

--- “Class III high-risk medical device clinical trial approval service guide

Clinical trial approval submission information should include a summary of animal experiments.

--- Guidelines for Preparation of Submission Information for Clinical Trial Approval of Passive Implantable Medical Devices

Selection of animal models:

Dogs: cardiovascular devices, cardiac electrophysiology, heart failure, urinary, neurological conditions

Sheep: heart valves, peripheral vascular, ophthalmology, plastic surgery/orthopedics

Goat: orthopedics, neuromodulation

Pig: cardiovascular devices, peripheral vascular, heart failure, trauma repair

Rabbit: general implant effects (subcutaneous/muscle implants), vascular, orthopedics, tendon repair

Rat: toxicologic response, general implantation effects (subcutaneous/muscle implantation)

Guinea pig: toxicologic response, general implantation effects (subcutaneous/muscle implantation)



4. Product agent registration (CFDA, FDA, CE)

未标题-1.png



5.Shelf life & packaging validation

未标题-1.png


Executive Standards:

ASTM F 1980-16, ISO 11607-1:2019, GB/T 19633.1-2015, ASTM F2096-11, ASTM F1140/F1140M-2013, ASTM F88/F88M-15, ISO 11607-1:2019, ASTM F1929-15, ASTM D 3078-02(2013), DIN58953-6:2016, ASTM F2096-11, YY/T0681.1-2018, GB/T 4857.1-2019, etc.


Item (Parameter) Name:

Accelerated aging, sealing strength test, dye penetration test, vacuum leakage test, microbial barrier test, bubble test, burst test, creep test, transportation simulation test, etc.



6. Cleaning and disinfection verification

未标题-1.png


Different microorganisms have different sensitivities to the chemical biocides or disinfectants they come into contact with. Free consultation phone: 13524733472
The nature of the disinfectant is different, the killing power of the disinfection process is different. Common disinfection can be divided into high, medium and low level disinfection.
* Low level disinfection: can kill bacterial propagules, certain fungi and lipophilic viruses. Low-level disinfection cannot be relied upon to kill mycobacteria, bacterial spores, or hydrophilic viruses.
* Medium level disinfection: kills viruses, mycobacteria, fungi and bacterial propagules, but not bacterial spores.
* High Level Disinfection: High level disinfection kills all microorganisms except a large number of bacterial spores.


Based on standards:

iso 17664, iso 17665-1, iso 15883-1, iso 15883-2

WS 310.1 Hospital disinfection supply center: Part 1: Management specification

WS 310.2 Hospital disinfection and supply centers: Part 2: Code of practice for sterilization techniques for cleaning and disinfecting machines

WS 310.3 Hospital disinfection supply centers: Part 3: Sterilization effect monitoring standards for cleaning and disinfecting machines

WS/T 367 Technical specifications for sterilization in medical institutions

Guiding Principles for Technical Review of Registration of Reprocessing Instructions and Confirmation Methods for Reusable Medical Devices (II) (Draft for Comments)

YY/T 0802 Sterilization of medical devices Information provided by manufacturers for handling reusable sterilized medical devices

GB 18278.1 Sterilization of healthcare products wet heat Part 1: Requirements for the development, confirmation and routine control of the sterilization process of medical devices

YY/T 1623 Sterilization of medical devices Information provided by manufacturers on the handling of re-sterilizable medical devices

YY/T 0734.1 Wash sterilizers Part 1: General requirements and tests

YY/T 0734.2 Washers and sterilizers Part 2: Requirements and tests for washers and sterilizers for moist heat sterilization of surgical and anaesthetic instruments, etc.

YY/T 0734.5 Part 5: Requirements and tests for sterilizers for chemical disinfection of non-invasive medical devices not resistant to high temperature.


Main instruments:


Classify

Instrument Name

Abbreviation

Application

NMR

Nuclear Magnetic Resonance

NMR

H spectrum, C spectrum, P spectrum, F spectrum, DEPT spectrum, two-dimensional spectrum (HMQC, HSBC, COSY, NOSY, etc.)

Test

Fourier Transform Infrared Spectrometer

FTIR

Structural identification, functional group analysis, qualitative analysis of compounds


Energy dispersive X-ray fluorescence spectrometer

EDXRF

Qualitative and semi-quantitative analysis of main elements (Na11- U92)


Wavelength dispersive X-ray fluorescence spectrometer

WDXRF

Qualitative and semi-quantitative analysis of main elements (B5- -∪92)


X-ray traversing instrument

XRD

Study on the crystal morphology of organic and inorganic substances, qualitative analysis of crystalline substances, semi-quantitative analysis of metal oxides


Inductively Coupled Plasma Spectrometer

ICP

Can provide qualitative and quantitative analysis of more than 70 elements

colour

spectrum

test

Gas Chromatograph

GC

Qualitative and quantitative analysis of organic matter


High performance phase chromatography

HPLC

Qualitative and quantitative analysis of organic matter


Gel chromatography

GPC

Molecular weight and distribution of polymers, proteins, etc. The number average molecular weight Mn, weight average molecular weight Mw, viscosity average molecular weight Mv, dispersity, and molecular weight distribution curve can be provided.


Ion Chromatography

IC

Qualitative and quantitative testing of anions and cations in aqueous solutions

Mass spectrometry test

Mass spectrometer

MS

Conventional mass spectrometry, high-resolution mass spectrometry


Inductively Coupled Plasma Mass Spectrometer

ICP-MS

Conduct qualitative and quantitative analysis of more than 70 elements


Gas Spectrometry

GC-MS

Separation of organic matter, qualitative and quantitative analysis


LC-MS

LO-MS

Separation of organic matter, qualitative and quantitative analysis


Pyrolysis GC-MS

PY- GO-MS

Qualitative and quantitative analysis of organic molecular compounds


Top air mass apectronmeter

Hs GC-MS

Solvent residue, aroma component analysis, qualitative and quantitative analysis of volatile organic substances

Electron ron

micr test

Scanning electron microscopy

SEM

Material morphology and organization observation


Transmission electron microscopy

TEM

Observe the morphology of nanoparticles and evaluate the particle size of nanoparticles


SEM-EDS combined analyzer

SEM-EDS

Material morphology, organization observation. Qualitative and semi-quantitative analysis of elements. For powder or relatively small solid samples, point, line and surface scanning tests can be performed.


7.IVD and physical and chemical testing  

未标题-1.png


Implementation standards:

GB/T 29791.1-2013, GB/T 29791.2-2013, GB/T 29791.3-2013, GB/T 29791.4-2013, GB/T 29791.5-2013, Product technical requirements.


Item (parameter) name:

Physical properties, analytical sensitivity, measurement precision, potency stability, accuracy, linear range, specificity, inter-batch variation, repeatability, etc.


Medical mask testing

Execution standard:

Medical mask material specifications ASTM F2100-2019, medical masks Requirements and test methods EN 14683-2019, respiratory protection devices Filtering half masks for particle protection Requirements, testing and labeling BS EN 149-2009, single-use medical masks YY/T 0969-2013, medical surgical masks YY 0469-2011, GB19083-2010 and other technical requirements for medical protective masks.


Item (Parameter) Name.

Appearance, airflow resistance, ventilation resistance, structure and size, nose clip, mask strap, sodium chloride particle filtration, pressure difference, flame retardant properties, Pseudomonas aeruginosa, total number of fungal colonies, coliforms, Staphylococcus aureus, hemolytic streptococcus, filtration efficiency, surface resistance to humidity, ethylene oxide residue, etc.


Medical protective clothing testing

Implementation of standards:

Respiratory protection devices Filter half masks for particle protection requirements, testing and labeling BS EN 149-2009, protective clothing Performance requirements and test methods for protective clothing against infectious agents EN 14126-2004, GB19082-2009 and other medical disposable protective clothing technical requirements, FDA registration and so on. Free consulting telephone: 13524733472


Item (Parameter) Name.

Sodium chloride particle filtration, ethylene oxide residue, appearance, structure, number specifications, water permeability, moisture permeability, surface moisture resistance, breaking strength, elongation at break, flame retardant properties, antistatic properties, static attenuation properties, bacterial colonies, coliforms, Pseudomonas aeruginosa, Staphylococcus aureus, hemolytic streptococcus, fungal colonies, logo, instruction manual, and so on. Free Consultation:13524733472


关于飞凡

ABOUT FEIFAN

飞凡检测致力于打造国内专业的第三方检测服务公司,不断优化整合市场检测资源,飞凡检测与多家科研院所,如上海同济大学,苏州大学,以及国内众多知名的检测公司进行深度合作,共同为国内制造业服务,为中国的制造业开拓海外市场保驾护航,为我们日常生活的健康安全树立标杆;公司目前工程师百余人,95%以上是本科以上学历;我们合作的实验室通过CNAS,CMA(EZ),所出具的任何一张报告都有CNAS,CMA资质,确保出具的每份报告都具有权威的法律效力。

为什么选择我们

市场需求和成熟的模式给了我们成功的保证
  • 行业认可
    CMA、CNAS资质大型研究型检测机构
  • 硬件实力强
    飞凡标准化实验室,经验丰富的技术团队
  • 技术优势
    13年领域聚焦,提供完善的解决方案
  • 服务周到
    飞凡全程专人服务,智能查询自助进度推送系统
  • 科学严谨
    飞凡标准化实验室,经验丰富的技术团队
  • 双C资质
    CMA、CNAS资质大型研究型检测机构
  • 品质服务
    飞凡完善的服务,效率高、周期短、数据准确
  • 专业公正
    飞凡公正、严谨,权威第三方检测机构